Menu
Překladač (translate)
Breadcrumb navigation

Introduction > Range of Products > Thermal Oil Boilers

Thermal Oil boilers

 

 Technical parameters and sizes of boiler VHK

Boiler type / size

VHK

2

Max. heat output

kW

1700

Rated output

kW

1500

Min. heat output

kW

200

Rated pressure / constructive pressure

 MPa

0,6/1,2

Max. temperature of output oil

°C

300

Min. temperature of input oil

°C

70

Resistance of flue gases

Pa

400

Capacity of pressure unit

l

1600

Service weight

t

6,78

Shipping weight

t

5,50

Charge of fundament

kPa

100

Boiler's length   

L

mm

3250

Boiler's width                              

B

mm

2000

Boiler's height

H

mm

2260

Height of the smoke adaptor axis

H2

mm

1170

Diameter of smoke adaptor

D3

mm

610

Output socket

PN 16

mm

100

Input socket

PN 16

mm

100

Safety socket

PN 16

mm

25

Boiler drainage

PN 16

mm

20

Height of opening for burner

H1

mm

1090

Opening for burner (max)

D0

mm

270

Length of combustion chamber

L1

mm

2630

Diameter of combustion chamber

D1

mm

980